33 Summer st, Pawtucket, RI 02860 massdusters@gmail.com
(508) 343-8014

Install

Service Overview

Dryer vent Installation

Having us properly install your dryer vent system will ensure that your dryer vent operates safely and efficiently. Dryer vent lint is flammable, and the more that accumulates in the dryer vent and the Dryer Vent, the greater the risk. The most obvious deterent to this is to have your dryer vent system properly installed. Building codes are in place for your safety that is why our professional dryer vent installations exceed current building codes.

A dryer vent system is designed to remove heat, moisture and lint from your dryer vent and if you have a gas dryer vent it also exhausts carbon monoxide which can be life threatening. Improper venting can cause a dryer vent fire and could lead to carbon monoxide poisoning.

Homeowners have been known to replace their dryer vent because they think it isn’t drying properly, when in reality most of the time the dryer vent system is the problem. The cost of repairing or replacing a dryer vent system may be a fraction of the cost of a new dryer vent. Buying a new dryer vent will not make the dryer vent system operate more efficiently it will also operate badly if the dryer vent system is malfunctioning or dirty. If you are having problems with your dryer vent system, give us a call, we can help.

Improper Materials Used for Venting

Improper installations on Dryer Vent are rampant. The most obvious, and possibly most common defect, is plastic dryer vent. Plastic is not allowed for Dryer Vent because lint can easily accumulate in the Dryer Vent when it sags and in its corrogated foldings, and besides that, plastic will not contain a fire. Flexible foil Dryer Vent are not much better than plastic. Any plastic or aluminum foil Dryer Vent should be considered a potential fire hazard, and should be replaced with rigid metal. If flexible material must be used, the code says it should be limited to a maximum of eight feet, and flexible metal should be used in transitions. In thepicture below I’ve included four types of pipe for you to familiarize yourself with. They are numbered here for easy reference. Two are recommended and two are rejected by state codes.

Dryer Vent construction

It is important that Dryer Vent vent to the exterior of the home and not into attics or other enclosed areas which can become a breeding gound for molds. The code says they should be made from metal, at least 4″ in diameter, and have a smooth interior. The entire Dryer Vent needs to be supported and secured, and no screws are allowed on the joints because they could accumulate lint. By code flexible materials, such as foil, plastic, and semi-rigid metal are not allowed in order to eliminate potential fire hazards.

Here are some of the stats we observe from the International Residential Code book:

  • All Dryer Vent must be a minimum of 4″ in diameter. Clean, unobstructed, frictionless Dryer Vent encourage air flow efficiency, quickens drying times, adds longevity to clothing’s life and reduces utility bills.
  • Flexible transition hose between the dryer vent and the wall outlet should be either the foil type or the aluminum flexible Dryer Vent (most preferred). Do not use the plastic or vinyl.
  • Concealed Dryer Vent must be rigid metal (galvanized or aluminum) Dryer Vent.
  • Dryer Vent joints shall be installed so that the male end of the Dryer Vent points in the direction of the airflow.
  • Joints should be secured with metal tape (not Dryer Vent tape). Do not use rivets or screws in the joints or anywhere else in the Dryer Vent as these will encourage lint collection.
  • Length of concealed rigid metal Dryer Vent shall not exceed 25 feet. Dryer Venting 5 feet from the allowable length for every 90 degree elbow and two and a half feet for every 45 degree fitting.
  • Concealed Dryer Vent must be rigid metal (galvanized or aluminum) Dryer Vent.
  • Dryer Vent joints shall be installed so that the male end of the Dryer Vent points in the direction of the airflow.
  • Joints should be secured with metal tape (not Dryer Vent tape). Do not use rivets or screws in the joints or anywhere else in the Dryer Vent as these will encourage lint collection.
  • Dryer vent shall be independent of any other systems (chimneys or exhaust vents)
  • Termination of dryer vent must be to the exterior with a proper hood or roof jack equipped with a backdraft damper. Small orifice metal screening should not be part of the hood or roof jack as this will catch lint and block the opening in a very short time. The hood opening should point down and exhibit 12 inches of clearance between the bottom of the hood and the ground or other obstruction.

PVC Dryer Venting should nor be used for dryer vent exhaust.

Many contractors unknowingly think one pipe is as good as another and that simply is not the case. PVC pipe does creates its own problems when used as exhaust pipe. Although it is smooth on the inside it is not appropriate for exhausting hot moist air and lint . There is a static charge that is created in platic pipe which causes the lint to cling together and with add moisture content causes the lint to cling to the walls of PVC pipe which over time, inevitably leads to a blockage in the pvc pipe. It is better to avoid pvc for dryer vent exhaust and use the recommended rigid metal Dryer Venting instead.

Backdraft Damper Must be Used

Wherever the Dryer Vent vents to the outside it needs to have a backdraft damper. This keeps intruders out when properly maintained. Also there should be no screens included at the end of the dryer vent exhaust vent. Some people install screens because they are concerned about animals getting into the Dryer Vent work. However if the backdraft damper is maintained through regular cleaning, this should not be a problem. When screens are installed, they can easily get clogged with lint. This will obviously reduce your dryer vent effectiveness to eliminate the moist hot air and create a blockage which becomes potential fire hazard

Good Practices to Observe

Periodically check the damper at the exterior to make sure it’s clean; when lint accumulates at the damper it will eventually cause the damper to stay open. If you’re unfortunate enough to have a dryer vent that exhausts through the roof… you may need a professional to clean that for you because someone needs to get up to the roof line on a regular basis to clean the damper and a professional company has the tools to do so.

Very often a Dryer Vent may be routed through a wall into a concealed area of the home, such as an attic or crawl space, you should check on it regularly to make sure that everything is functioning properly and is still connected. A disconnected clothes Dryer Vent will release a considerable amount of lint and moisture in to the home. Therefore you should inspect those areas and also to Inspect behind your dryer vent to check for build up of lint- it is a common problem for the dryer vent to become disconnected from the Dryer Vent because of the force from the dryer vent er exhaust. This can create a pile of flammable lint behind the dryer vent. As a regular part of dryer vent maintenance; the dryer vent Dryer Vent  itself needs to be cleaned .

Another common installation defect is the length of the Dryer Vent. The inspection code says that Dryer Vent should be no longer than 25 feet. It states that for each 90 degree turn, you must subtract 5 feet. Many Dryer Vent are configured so that they make a 90 degree turn when the Dryer Vent comes out of the dryer vent. From there it may run up to the ground level if in a basement which may be another 8ft then again make another 90 degree turn to face the exit area for the exhaust. If you add the length it will take to reach the outside of the home you can see that it doesn’t take long to reach this maximum recommended length. It is important to refer to your dryer vent installation manual to determine the manufacturers recommendation. The code says the manufacturer has the last say as to how far the dryer vent length shall be and allows for a longer run if the manufactureer says it can do so.